Description
Air Leak in Priming System
Causes: Prime pump
Remedy
Remote troubleshooting (call agent)1. Switch the power off and disconnect the power cord. Reconnect the power cord and power on the printer.2. The call agent should arrange a service engineer visit to check or replace the prime air circuit, and follow the Onsite troubleshooting below.3. If a different system error is displayed then the call agent should perform the applicable troubleshooting procedure.Onsite troubleshooting and solution (service engineer)1. Switch the power off and disconnect the power cord. Reconnect the power cord and power on the printer.2. Remove the covers and check that the Prime Pump air circuit has a leakage, and inspect fluidic connections or replace them.IMPORTANT:If fluidic connections are disconnected, reconnect them and ensure they are properly fit.3. If still there’s an obvious leakage, replace them: Fluidic pump . carriage circuit4. Replace the Pump motor, see Prime Pump. Prime pump.