Description
PPS system failure.
Remedy
• Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that the Pen to Paper Space (PPS) Solenoid cable is not damaged and is correctly connected to the PrintMech PCA. • Perform the Scan Axis PSS diagnostic test to troubleshoot the problem further . Page 3-9. • Make sure the Service Station is correctly installed. Sometimes, if the Service Station is not correctly installed, the front of the Service Station falls down (causing the Service Station to be tilted), and the L-Bracket support does not fit properly. The front of the Service Station should be “UP,” and the L-Bracket should fit well with the Service Station. • Replace the Pen to Paper Space (PPS) Solenoid. • If the System Error continues, replace the PrintMech PCA.