Description
Ink Supply Station failure.
The possible cause could be: 1. Reading, writing or initializing the backup EEROM failed. 2. One of the out-of-ink sensors (located in the Ink Supply Station) is not reporting what it should during the initializing process while depressurizing.
Remedy
Replace the Ink Supply Station