Code 94:08

Description Color Calibration Warning – Color Calibration not cancelled but Color Calibration values are likely to be incorrect. Remedy Try the Color Calibration again, but this time using a differnt type of media

Code 94:10

Description Color Calibration Failure – Color Calibration cancelled. Remedy Unplug the power cable from the printer and wait a few seconds. Plug in the power cable again and try the Color Calibration again. ?If this error code appears again, check…

Code 95:00

Description Printhead Alignment Failure – Printhead Alignment cancelled. Remedy Clean the printhead indicated by the printer. ?If the error code continues, replace the faulty printhead.

Code 95:02

Description Printhead Alignment Failure – Printhead Alignment cancelled. Remedy Unplug the power cable from the printer and wait a few seconds. Plug in the power cable again and try the Printhead Alignment again. If this error code appears again, check…

Code 81:01

Description Paper-Axis shutdown – usually a paper-jam caused by a blockage of the Paper-axis System. Remedy If this error code was caused by a paper-jam, unplug the power cable from the printer and clear the blockage. Plug in the power…

Code 81:01

Description Paper-Axis shutdown – usually a paper-jam caused by a blockage of the Paper-axis System. Remedy If this error code was caused by a paper-jam, unplug the power cable from the printer and clear the blockage. Plug in the power…

Code 85:10

Description Paper-Axis Encoder error. Remedy Make sure that the Encoder Sensor cable is connected correctly. ?Replace the Paper-Axis Motor Drive Assembly. ?Replace the Electronics Module

Code 12:11

Description A short detected in the Carriage Assembly. Remedy Remove ALL the Printheads and clean the flex contacts on the Printheads and in the Carriage Assembly. Replace ALL the Printheads. Replace the Carriage Assembly

Code 21:10

Description Service Station failure. The possible cause could be: 1. The steps counted by the Service Station motor are not consistent with the expected length of the current movement. 2. The Aerosol Fan has reached its maximum current limit. 3.…