Code 07.02:11
Description USB Cable not connected Remedy 1. Check the condition and connections of the USB cable, replace if necessary.
Description USB Cable not connected Remedy 1. Check the condition and connections of the USB cable, replace if necessary.
Description DelSol3 ASIC not found or not responding Remedy 1. Check the condition and connections of the Interconnect data and power cable, replace if necessary
Description Failure reading/writing NVM in Hard disk Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Replace the Hard Disk.
Description Problem with Power Supply Unit Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Replace the Power Supply Unit (PSU). See…
Description Battery of Real Time Clock ran down Remedy Replace the battery.
Description Communication with Engine PCA failed Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Remove the Formatter and reinsert it again.…
Description Roll 2 switch failed (standby or resume). Roll 2 has been unloaded. Remedy There is no corrective action. This system warning code only notifies the user that the roll has been unloaded because an unexpected error occurred with Roll…
Description Roll 1 switch failed (standby or resume). Roll 1 has been unloaded. Remedy There is no corrective action. This system warning code only notifies the user that the roll has been unloaded because an unexpected error occurred with Roll…
Description Ink supply error found during IDS diagnostic test. In the Touch Control Panel message you will see letters representing the names of the colors of the faulty supplies. Remedy 1. Reseat the faulty ink supply and repeat the Ink…
Description Ink Setup failure Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Insert the new purgers, reconnect the power cord and power on the product. 2. Perform the Ink Delivery System…
Description Left Ink Supply Station error, module 1 Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Check that the cables between…
Description Left Ink Supply Station error, module 0. Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Check that the cables between…