Code 86:01
Description Scan axis error—the copier will restart and run a diagnostic test Remedy None
Description Scan axis error—the copier will restart and run a diagnostic test Remedy None
Description Scan Axis movement requires too much force or energy. Remedy 1. Check that the cutter disengages correctly. 2. Lubricate the scan axis. 3. Use Preventive Maintenance Kit 1.
Description Problem finding the Scan-axis encoder reading Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Make sure that the encoder strip…
Description Problem with the Carriage Encoder Sensor readings Remedy 1. Check that the encoder sensor is correctly connected to the Carriage PCA. 2. Make sure the Encoder Strip is not broken or damaged. If necessary, replace it. See Encoder Strip,…
Description Unable to pressurize the Ink Delivery System Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Perform the Ink Delivery System…
Description Error Codes Format: • XX: Subsystem or process (2 digits). • n: Subsystem or process index (if more than one used in the product) – optional. e.g. Identify the Ink Supply (color and number). • Y: Who should perform…
Description An unsupported or reused part has been installed. Remedy Install only new parts recommended by HP for this product.
Description Cannot retrieve IP addess Remedy 1. Connect to another network. 2. Modify the IPv4 configuration.
Description Input/Output problem through the network interface of the Formatter Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Check that the…
Description The External Hard Disk accessory does not seem to be connected Remedy 1. Switch the power off from the back of the product. Connect the External Hard Disk accessory, check that the USB cable is properly connected and power…
Description Input/Output problem through the USB Port Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Check that the USB cable is…
Description Memory Driver Internal I/O error, I/O Socket Manager Internal I/O error Remedy 1. Switch the power off from the back of the product and disconnect the power cord. Reconnect the power cord and power on the product. 2. Check…