O2ML9YjB9mA2

O2ML9YjB9mA2

Code 65:YZ

Description Memory Driver Internal I/O error, I/O Socket Manager Internal I/O error. Remedy • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check…

Code 68:YZ

Description Loss of engine counters tracking. Remedy • Reboot the printer. The printer will continue to function correctly, but the life counters will not continue counting until you restart the printer.

Code 71:19

Description Default Serial Number found in the main and backup NVM. It seems that both the Print Mech PCA and Hard Disk Drive have been replaced together. Remedy • Perform the “Error 71:19 Recovery” Service Utility.You MUST NEVER replace both…

Code 71:YZ

Description Out of memory failure. Remedy • It is recommended that you remove any unnecessary files from the Hard Disk Drive of the Formatter using the Web Server. • If there seems to be a problem with the HP-GL/2 driver,…

Code 72:YZ

Description A service calibration must be performed. Check the internal error code to see which calibration must be performed. To check the internal error code, press UP and CANCEL together while the error code is displayed. Remedy • 0x07090001 (gain).…

Code 74.1:YZ

Description Error uploading media profile update file. Remedy • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Make sure the connection between the…

Code 74:YZ

Description Error uploading firmware update file. Remedy • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Make sure the connection between the computer…

Code 77:YZ

Description Web access application. The web server is not functioning correctly. Remedy • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Check that…

Code 0000-0059

Description 00.00. Unknown Service Part Causes: 59. MOTOR_SERVO_SHUTDOWN Remedy Code: 0001-0082 Description: Real Time Clock (RTC) Battery ran down. Causes: Remedy: How to solve. Remote troubleshooting (call agent) 1. The call agent asks the customer to go to the Support…